I, the first non-laser light-emitting
1, according to the operation panel test key concept ammeter check status:
¢Ù no current: check the power of laser power is connected, whether loose or fell off high-tension line, the signal line is loose;
¢Ú current: check whether the broken lens, optical serious shift;
2, check water systems are in working order:
¢Ù water barrier: check whether the pumps damaged or no electricity;
¢Ú water: Check the intake, outlet access is the main burst, or anti;
3, fixed fire can and can self-test, do not send data LED (check computer settings are correct)
Second, carved or engraved with different depth is not deep
1, check whether the smooth flow of the water cycle system (or the Warping main burst water pipes);
2, check whether the normal focal length (re-calibration);
3, whether or not the normal optical inspection (re-calibration);
4, check whether the paper version of the material spread too thick, too much water, whether or not (re-corrected);
5, check whether the parallel beams (on both sides of the belt-conditioning);
6, check whether the broken lens (replacement);
7, check the lens or laser transmitter is contaminated (re-washing);
8, check the water temperature is higher than 30 ¡æ (the replacement of recycled water);
9, check the first laser-focus on whether or loose (step up);
10, laser light is required to achieve current 8ma;
11, laser aging tube (to replace: warranty free of charge);
Third, reset abnormal
1, check whether the sensor James Gray, bad or damaged (wipe the dust off the sensor or replacement);
2, the conduction band check soft data is bad or damaged lines (data lines cut or re-plug the replacement of the data lines);
3, check the reliability of ground contact or whether the damaged high-tension line (re-grounding or replacement of high-tension line);
4, bad electrical lines.
Fourth, Louke
1, initialization is not correct, the data has been sent (corrected);
2, reversed the order of operation (re-exports);
3, static (check off whether or not ground);
V. Goubian sweeping dislocation, is not closed
1, edited document is correct (re-editing);
2, the target is in excess of the selected layout (re-selected);
3, the software checks whether the parameters set correctly (reset);
4, computer system error (re-install the software and system-speaking);
5, elastic belt around check whether the back-end or whether the belt is too loose (to step up belt);
6, or synchronous belt check whether the round of the skid, jump teeth (or intensified round of the synchronous belt);
7, check whether the parallel beams (about re-regulating belt);
Sixth, the computer can not output
1, the software checks whether the normal parameters set (reset);
2, engraving machine is re-exported to their starting position (re-exports);
3, check in advance whether or not reset the machine (to correct);
4, check whether the serial output and the software set up the same serial port (reset);
5, check the reliability of ground wire, whether or not static interference data line (to ground);
6, the replacement of computer output serial test;
7, re-install the software and re-test set;
8, to format a computer disk system to re-install the software testing;
9, serial board need to repair or replace damaged.
Seven can not be calculated path
1, check the path set up the calculation is correct;
2, check graphics file formats are correct (re-corrected);
3, removed and re-install the software settings;
Eight computer Frequently Asked Questions
1, gradually reduce the font (re-install the operating system);
2, the amount of data can not be too calculating the path of laser (or wait for some time to increase computer memory);
3, did not respond to calculate the path for a long time, restart the computer test.